Comment Re:What Material Is the Pantacene Sitting On? (Score 4, Informative) 169
Sorry to reply to myself, but here's the most important reason for the lack of substrate heterogeneity in the image:
"The AFM images (Fig. 1, C and D) were recorded in constant-height mode; that is, the tip was scanned without z feedback parallel to the surface while the frequency shift {Delta}f was being recorded (16). In this and all of the following measurements, the tip height z is always given with respect to the STM set point over the substrate."
In school, when I ran AFM I allow feedback from the tip to adjust the height of the probe so that it maintains contact with the thing I'm imaging, regardless of topography. Here, they had a very smooth substrate and then set the height of their probe to a fixed position above it.