Follow Slashdot blog updates by subscribing to our blog RSS feed

 



Forgot your password?
typodupeerror
×

Comment Re:Yeah, it was her fault (Score 1) 698

"Night mode" still requires a light source. Usually it's infrared. Since it's out of the visible range, it keeps the illusion of 'night'. The car already had headlights that both the 'driver' and camera can use- no sense in adding special IR headlights that only benefit the camera.

Comment Re:Snake Pliskin Style! (Score 2) 244

Get a Pebble. Half the price, and does all the things you just mentioned, plus more.
Black & White ePaper screen, but that means it stays on all the time and the battery lasts a week. Easily readable in sunlight, too.
No speaker or microphone on it, but unless you plan on talking into your watch, I don't see a problem :)

Comment Re:Glaring errors in the techweek article. (Score 1) 196

It seems like they put something extra in the pen cartridges that they don't have in the vials. I remember using the same pen cartridges for closer to a month before they ran out, rather than went bad. But I'll notice that the humalog that I load into my pump start to lose its effectiveness closer to a week. Its also slightly above room temp sitting in my pocket.

You're supposed to change lancets?

Comment Re:Glaring errors in the techweek article. (Score 1) 196

Insulin only lasts a week or so unrefrigerated, and that's at room temperature. I'd imagine it would be significantly less when warmed to internal body temp. Either way, nowhere near 45 days.
Also (because of the point above), the only reason to carry more insulin would be due to insulin resistance in the user. Meaning that the so-called "deadly" dose would have even less effect.

Encryption

Submission + - Pakistan Bans Encryption (techdirt.com)

An anonymous reader writes: After some rumors of this last month, Pakistan has now officially told all of the country's ISPs that they need to block all encrypted VPNs since content running over such things cannot be monitored by the government.

Comment Re:Pump User Here: (Score 1) 81

What else would a hack simulate but the signal source? In my first two instances, bad data is introduced, but there is no danger to the patient. In the third, bad instructions may be sent, but they are echoed by the pump before starting. In the fourth, you not only have to have a valid serial to simulate, but you have to address it directly to another serial.
Did you read the article? The would-be hacker HAS the serials of his own devices, and still hasn't figured out how to hack them.

Comment Pump User Here: (Score 1) 81

I realize many of these points are pointed out in the article, and I will be repeating them here for those of you who didn't read it:

There are several types of wireless communication built into my pump (A Minimed 722 with a CGMS sensor):
1.) Sensor (inserted elsewhere into body) sends current glucose level to pump
- Requires the sensor serial to be entered into the pump
- If hacked, would report a false glucose level to the pump. The pump NEVER acts on it's own, it only informs you of what the level is, so no danger. Also, for any treatment you are supposed to double check the level with a finger-poke as below.
- Also, if a level is reported that is out-of-pattern with the rest of values that the pump has been receiving, the pump assumes that the sensor is out of calibration or failing, and has you re-calibrate the sensor with a finger-poke.

2.) Meter (regular old finger-pokes) sends current glucose to monitor
- Requires meter serial to be entered into the pump.
- If hacked, the meter and the pump would show different numbers, making the manipulation obvious. Also, if someone randomly started sending values to my pump, I would know due to the fact that I wasn't currently checking my glucose.

3.) Remote sends instructions to deliver insulin
- Requires remote serial to be entered into pump
- Pump still vibrates/beeps to confirm delivery and dosage. Not exactly discrete.
- I'm not sure what other safeguards this has. I don't use it. I do know that if you don't have any serial numbers entered, it turns this feature off.

4.) USB Device gathers reports/programs pump
- Requires pump serial to be entered into computer.
- The 'USB Device' mentioned in the article is almost certainly a Carelink USB Upload device, used to upload data from the pump to a computer for gathering reports on glucose trends, patterns, other ways to fine-tune your treatment.
- I do know that these CAN be used to upload new settings to the pump, as I've seen them do it at my doctor's office.
- User software doesn't feature upload capability, so hackers would need to steal a copy of the 'pro' software from a doctor's office (additional security through obscurity?)

Of the four, the last two are the only ones that could alter insulin delivery, and the last one is the only one that would do it without notifying the user. You would have to develop a profile that had a high basal rate (background, continuous insulin delivery). Again, you would still need to get the serial number off the pump to initiate the upload.