Comment Re:Its not the CFL/LED (Score 1) 602
It depends on the start mechanism of the ballast. Rapid start and programmed start ballasts give very good electrode life, but at the cost of reduced efficiency. Instant start is most efficient, but it substantially reduces electrode life. Given that lamps are generally rated for substantially longer life with programmed start than instant start, electrode life must be the limiting factor in at least some cases.